Methodology

How monytr calculates CO₂ and energy.

Methodology version 1.0 · 15 November 2026

This page explains how monytr calculates the CO₂ and energy figures for your machines and vehicles, so that you, your client or your auditor can check every figure.

Principles.

  • We follow the GHG Protocol Corporate Standard (2004): Scope 1, Scope 2 and the relevant parts of Scope 3.
  • Scope 2 is location-based: the country's average grid factor, unless you enter your own electricity contract's factor.
  • Biogenic CO₂ from biofuels is reported separately, outside the scopes.
  • Nothing is offset or netted. "Saved compared with diesel" is never subtracted from any total.
  • Emission factors are used exactly as published, with their source and edition.

What we calculate.

FigureHow
Scope 1Fuel × tank-to-wheel factor
Scope 2Electricity used by the machine or vehicle × grid factor (or contract factor)
Scope 3.3Fuel and electricity × well-to-tank factor (production and transport)
Well-to-wheelFuel × published well-to-wheel factor
Biogenic CO₂Fuel × biogenic factor, shown separately
EnergyFuel × heating value + electricity, in MWh, renewable and non-renewable

Where the fuel data comes from.

For each machine and period we use the best available source, in this order:

  1. the machine's fuel counter;
  2. the consumption the machine reports itself;
  3. an average consumption you enter;
  4. an estimate from operating hours and engine power, using the European emission inventory guidebook method (EMEP/EEA);
  5. no data: the figure stays empty.

Every report shows coverage: the share of your operating hours that is measured, estimated or unknown. Unknown is never counted as zero.

Emission factors.

Your company's countryFuelsElectricity
Belgiumco2emissiefactoren.be (valid since 1 January 2023)Grey electricity Belgium (list 2023, data 2022)
Netherlandsco2emissiefactoren.nl (2026 edition)Grid mix Netherlands 2026
Other EU countriesBelgian listEEA figure for that country
OtherBelgian listEU average
  • A value missing from the Belgian list? That applies to LPG, biogenic CO₂ and heating values. We then use the Dutch value and say so. HVO30 is calculated from HVO100 and fossil diesel (30/70).
  • Each year uses that year's factors, or the latest available edition. A new edition never changes years already reported. Only a correction of an error does, and we record it.
  • Rounding: the lists round each value separately. As a result, Scope 1 + Scope 3.3 can differ from the published well-to-wheel total by at most 0.001 kg per litre.

Electricity.

  • We report the electricity used by the machine or vehicle itself, excluding charging losses. Your full Scope 2 comes from your electricity bill.
  • For machines that can run on diesel or on mains power, we use the share of operating hours on mains that you enter.

Energy.

  • Heating values come from co2emissiefactoren.nl, e.g. 35.9 MJ per litre for pump diesel B7.
  • The renewable share is calculated by energy content, not by volume: B7 is 6.4% renewable. For electricity we use the national share, or your contract's share if you enter it.

Limits.

  • No market-based Scope 2 beyond an entered contract factor.
  • No Scope 3 categories other than 3.3.
  • monytr is not a certification or audit: your certification body assesses your inventory.

Changes.

VersionDateChange
1.015 November 2026First publication

Back to CO₂ reporting · Try the free CO₂ calculator